Set/reset reg.         index 00h  GRAPH

Layout b3-b0 S/R Set / reset

The bit positions of this field correspond to the respective
display planes and to the bit positions in the Enable
set/reset register. The display planes that correspond to the
bits enabled in the Enable set/reset register will be modified
by the corresponding bits in this Set/reset register. This
allows up to four display planes to be modified with unique
data in a single operation.