Int E0 - Dr Multiuser Dos - "a_control" - Get/set Aux Control Parameters [O]

CL = B1h
DS:DX -> AUX device control block (see #3704)

Return: AX = status
0000h successful
control block updated
FFFFh failed
CX = error code

Note: also supported by REAL/32

See Also: INT E0/CL=B0h,INT E0/CL=B2h

Format of DR Multiuser DOS AUX device control block:
Offset Size Description (Table 3704)
00h BYTE function (00h get, 01h set)
01h BYTE DTR state (00h low, 01h high, FFh unknown/don't change)
02h BYTE RTS state (00h low, 01h high, FFh unknown/don't change)
03h BYTE DSR state (00h low, 01h high, FFh unknown/don't change)
04h BYTE CTS state (00h low, 01h high, FFh unknown/don't change)
05h BYTE DCD state (00h low, 01h high, FFh unknown/don't change)
06h BYTE RI state (00h inactive, 01h active, FFh unknown/don't change)