Int 68 Fn 01 - Appc/pc - Network Device Control - Attach Physical Unit [N]

AH = 01h subfn 2000h
DS:DX -> control block (see #3340)

Return: control block updated

See Also: AH=01h/SF=2100h,AH=01h/SF=2B00h

Format of APPC/PC "Attach Physical Unit" control block:
Offset Size Description (Table 3340)
00h 12 BYTEs reserved
0Ch WORD 2000h (verb "Attach Physical Unit")
0Eh 6 BYTEs 00h
14h DWORD (big-endian) return code (see #3339)
18h WORD 00h
1Ah BYTE version
1Bh BYTE release
1Ch 8 BYTEs (big-endian) net name
24h 8 BYTEs (big-endian) physical unit name
2Ch 8 BYTEs 00h
34h DWORD pointer to SYSTEM_LOG_EXIT routine, FFFFFFFFh=don't log errors
(see also AH=01h/SF=2100h)
38h DWORD 00h
3Ch BYTE 00h RETURN_CONTROL: COMPLETE
01h RETURN_CONTROL: INCOMPLETE