Int 60 u - Hp 95lx System Manager - Set Communications Settings [b]

DI = 0E14h
STACK: 2 WORDs unused dummies (for calls from high level languages)
WORD comm channel handle
DWORD pointer to communications settings (see #2974)

Return: ???
STACK unchanged

See Also: INT 60/DI=0E15h

Format of HP 95LX communications settings:
Offset Size Description (Table 2974)
00h BYTE dial type ('T' tone, 'P' pulse)
01h WORD baud rate divisor (115200/baud_rate)
03h BYTE parity (00h none, 08h odd, 18h even, 28h mark, 38h space)
04h BYTE stop bits (00h one, 04h two)
05h BYTE data bits - 5
06h BYTE software handshake
01h none, 02h XOFF/XON, 04h XOFF/any, 08h ENQ/ACK
07h BYTE infrared (01h off, 02h on)
08h BYTE duplex (01h half, 02h full)
09h BYTE echo (01h echo, 02h no echo)