Int 21 Fn 5F3A U - Named Pipes - Local Dosrawwritenmpipe [N]

AX = 5F3Ah
BX = handle
CX = buffer length
DS:DX -> buffer

Return: CF clear if successful
CX = bytes written
CF set if error
AX = error code

Notes: this function was introduced by LAN Manager but is also supported by
the Novell DOS Named Pipe Extender, Banyan VINES, OS/2 Virtual DOS
Machines, and others
not documented in the LAN Manager Toolkit

See Also: AX=5F39h,AX=5F3Bh,INT 2F/AX=118Fh