Int 1Ah, 09h            Read Clock Alarm Time and Status          Convertible

Reads the alarm time and status from the real-time clock.

Entry AH = 09h

Return CF = Set if clock operating; else cleared
CH = Hours (BCD)
CL = Minutes (BCD)
DH = Seconds (BCD)
DL = Alarm Status
00h - Alarm not enabled
01h - Alarm enabled but will not power-on
system
02h - Alarm enabled and will power-on
system

──────────────────────────────────────────────────────────────────

Note that all dates are in Binary Coded Decimal (BCD). For
example, June 1, 1985 will be set as CX = 1985; DX = 0601.

The real-time clock is the clock that runs even when the computer
is turned off. A CMOS battery is used so that, even while the
computer is off, the date, time, and alarm time are maintained.

This service is available only for the PC Convertible. ATs and
XT-286s will set the Carry Flag, thus reporting an error state.
Previous machines will report unpredictable results (including the
state of the Carry Flag).